Table 4.5.3.9-2. Potential Radiological Impacts to Workers Resulting from Normal Operation of Stockpile Management Alternatives at Pantex Plant

Affected Environment No Action Single-Shift Operation Downsize Assembly/Disassembly Three-Shift Operation Phaseout Assembly/Disassembly and High Explosives Fabrication

Involved Workforce1
Average worker dose2 (mrem/yr) 10 10 0
25-year fatal cancer risk 1.0x10 -4 1.0x10 -4 0
Total dose (person-rem/yr) 10.7 3.0 0
Noninvolved Workforce3 (HE Fabrication)
Average worker dose2 (mrem/yr) 0 0 0
25-year fatal cancer risk 0 0 0
Total dose (person-rem/yr) 0 0 0
Total Site Workforce4
Dose (person-rem/yr) 10.7 3.0 0
25-year fatal cancers 0.11 0.030 0

1 The involved worker is a worker associated with operations of the A/D facilities. The estimated number of involved workers considered at risk for exposure is 300 for the downsize/consolidate alternative. The 1,070 workers for the No Action alternative are all considered at risk for exposure.

2 The radiological limit for an individual worker is 5,000 mrem/yr (10 CFR 835).

3 The noninvolved worker is an onsite worker unassociated with operation of the A/D facilities in question. The estimated number of noninvolved workers is 50.

4 The total site workforce is the sum of the number of involved and noninvolved workers. The estimated number of workers in the total site workforce is 350 for the downsize/consolidate alternative and 1,070 for the No Action alternative. Source: DOE 1993n:7; PX MH 1995a.